断桥铝门窗如何更换密封条?
来源: 2016-01-25 13:48:58
断桥铝门窗如何更换密封条?
Broken bridge aluminum doors and Windows to replace the sealing strip?
1)密封材料规格较多,可向厂家询问具体规格。
1) sealing material specifications, can ask manufacturer specifications.
2)更换准备:检查安装密封条的部位有无破损、变形;密封条的种类、规格、截面形状是否符合要求,有无缺陷或损伤。密封条应在清洁、干燥、温暖的环境下施工。济南断桥铝门窗
2) replacement preparation: check whether there is any breakage, deformation on installation of sealing part; Sealing strip type, specification, cross section shape is in accordance with the requirements, the presence of defects or damage. Sealing strip should be clean, dry, warm environment construction.
密封条安装前应进行松弛处理,使其消除卷曲包装时的形变,恢复弹性。方法是打开包装,将密封条平放或悬挂在支架上,在20℃左右的环境中处理24小时。冬季施工时,可用温水浸泡的方法处理密封条,但不允许直接用明火加热。
Sealing strip should be done before installation relaxation process, eliminating curling when packing deformation, elastic recovery. Method is open the packing, sealing strip flat or hanging on the scaffold, in about 20 ℃ environment treatment for 24 hours. When winter construction, can use warm water immersion method processing sealing strip, but are not allowed to directly use the firing.
清理窗框和密封凹槽,使其保持清洁、干燥。
Clean up the window frames and seal grooves, keep it clean and dry.
3)采用手工和滚压工具将密封条安装部位完全嵌入到异型材特设的嵌槽内。密封条装到窗的转角处时不要剪断,剪成45°角边缘要留一点相连,防止收缩时拉断出现开口。框扇之间密封条嵌装时要留出1%的余量,以防收缩断口。
3) the use of manual and rolling tools install the sealing parts completely embedded in different profile AD hoc embedded groove. Sealing strip into the corner of the window, don't cut, cut into 45 ° Angle edge to leave a bit to prevent shrinkage when pulled from opening. Box door sealing strip between embedded to set aside 1% of allowance, to prevent shrinkage fracture.
手工嵌装密封条时应特别注意:密封条不允许拉延。剪断时应留有收缩余量。若有断头,不要设在拐角处,更好在纵向位置,且将端口处对紧,并用粘合剂粘贴牢固。
Should pay special attention to: when manually flush seal sealing strip drawing is not permitted. Cut, shrinkage allowance shall be maintained. If you have beheaded, do not in the corner, the best in the vertical position, and the port to tight, and cement paste is firm.
4)框体的密封条,从左下角开始,顺时针旋转,沿胶条的槽口移动回到原位,注意要嵌入槽内并保存一定的伸缩余量。
4) the box body sealing strip, starting from the lower left corner, clockwise, along the strip rabbet moving back to the in situ, pay attention to embed groove and save some telescopic allowance.
5)如果要更换扇上的密封条,则起点需从扇上框的中间开始。
5) if you want to replace the sealing strip on the fan, the starting point to the middle of the box from the fan.